Back to Top

Hi, Guest!

GPRS Telemetry Data Logger MicroThings S200

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Rantai
Dilihat Sebanyak
:
98 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail GPRS Telemetry Data Logger MicroThings S200

Serial GSM GPRS Remote Controller is a universal GSM dialer and controller as well as a GSM GPRS Remote Control and Alarm Unit. it provides multi digital relay outputs( 120VAC/ 3A, 24VDC 3A, ) , upto 6 digital inputs( Opto-isolated, Active Contact, 3~ 24VDC, Completely isolated) .can be used as pulse counter inputs) , 2 temperature inputs for DS18B20, multi analog input( both of 0-20mA and 0-5V, 12 bit resolution) , RS485 Port( Support Modbus RTU Protocol, more protocols can be added according to application requirements) , reserved RS232 Serial Port and USB port for setting and download upgraded firmware by user on-site. It allows you to monitor and control an alarm or remote stations or equipments or machines by SMS( Short Message Service) Or GPRS. Another, it can transmit data from apparatus ( thermometer, humidity meter, electric meter, flowmeter, PLC) to user or monitoring center by GPRS. Serial GSM/ GPRS Remote Controller equipped Siemens MC55i quad-band GSM Module inside to make it is industrial class reliability, is a low cost, wireless M2M, wireless data logger, universal GSM GPRS Engine which can remote control outputs, transmit and receive analog, digital and pulse counter data, PLC, Varity metering equipments to any device connected to the Wireless GSM GPRS network such as mobile phones, Web Sites, monitoring center, control room, SCADA, etc. The GSM GPRS Remote Controller can be used as: 1. A Switch with SMS Remote Control. SMS texts for switching particular terminals on/ off are configurable. 2. A Timer-Switch which can be activated automatically. It can be used as preset time when the GSM GPRS Remote Controller need work and when it needn‘ t work. 4 daily timer and 7 Weekly Timers. 3. A Relay with dialling-in remote control. Up to 4 tel. numbers can be authorized for it. Because calls are not answered dialling-in control within GSM is free of charge. ( it only checks the caller’ s number and - if the number is authorized - responds with relay activation.) This can be used for parking latch control, gsm gate opener, remote control machine, etc. 4. An automation system. Each input can link to output actions, this is very useful when the temperature upto appointed value, need switch on the air-conditioning immediately, or when water overflow and need switch on the dryer, or when somebody broken into the door or windows need to start the CCTV and Siren. 5. A SMS reporter. The digital Inputs activations or deactivations can be reported by SMS and optionally confirmed by phone calls. Each input can have its own message texts and the message can be programmed by users. 6. A Pulse Counter. The digital inputs can be used as the pulse counter, the user can setup both of interval value activated alarm and total value activated alarm. 7. A Data Logger. The unit can save the all of the acquisition data in internal memory storage and upload to internet by GPRS network according to schedue, no distance limitation. 8. A Wireless Data Acquisition to SCADA or HMI or Monitoring Center. The unit can acquisition the varity data( E.g.: Pressure, Level, Current, Voltage, digital input status, pulse counter, digital relay output status, temperature value, humidity value and other) and upload to the SCADA( Real time dynamic data) or HMI or Mornitoring Center by SMS or GPRS, no distance limitation. 9. A Wireless Intelligent Meter Reader. The GSM GPRS Remote Controller can be used to read remotely intelligent meter data to SCADA or monitoring center by RS232 port or RS485 Port, at present supports ABB, KL, HHE intelligent meters by RS485, more special meters’ communication protocol can be add according to application requirements. 10. A GSM GPRS Remote Termials ( GSM GSM GPRS Remote Controller) . It can work with the supervisioning center, in the supervisioning center, the own can remote monitoring and control the remotely terminals by GSM GPRS Network.This is very useful to Fuel tank monitoring, Oxygen in hospital, Flood level, street light control, wellhead control, BTS environment monitoring, power transmission system monitoring and other applications. Spesification Anolog input: 4, 0-5V and 0-20mA, 12bits, can setup Hi- Lo Value to alarm; Digital Input: 2 Opt coupler inputs, NC/ NO Mode, can be used as Pulse Counter ; Digital Output: 2 Relay Outputs; Setup Method: PC Configurator via USB Port and SMS Commands or GPRS via internet; Temperature Input: 2, speical for DS18B20; RS485: 1, supports Modbus RTU as Master; Internal Memory: 4MB; Rated Voltage: 9-24VDC; SMS Alert Number and Alarm Dial Number: 6; Backup Battery: 7.2V 1200MAh LI-ION; GSM Freqency: 850/ 900/ 1800/ 1900Mhz.
Tampilkan Lebih Banyak